Engineering data
Technical datasheet
Specifications
- Construction
- Copper conductor / Kynar (PVDF) insulation / HMWPE sheath
- Cross-section
- 1×10 / 1×16 / 1×25 / 1×35 mm²
- Rated Voltage (Uo/U)
- 0.6/1 kV
- Conductor
- Copper, stranded
- Wires: Number × Diameter (mm)
- 1×10: 7×1.36 / 1×16: 7×1.74 / 1×25: 7×2.15 / 1×35: 7×2.63
- Conductor Diameter (mm)
- 1×10: 3.84 / 1×16: 4.85 / 1×25: 5.94 / 1×35: 7.15
- Max. DC Resistance at 20°C (Ω/km)
- 1×10: 1.83 / 1×16: 1.15 / 1×25: 0.727 / 1×35: 0.524
- Primary Insulation
- Kynar (PVDF), nominal thickness 0.70 mm (all sizes)
- Outer Sheath
- HMWPE, nominal thickness 1.65 mm (all sizes)
- Approx. Weight (kg/km)
- 1×10: 141 / 1×16: 202 / 1×25: 290 / 1×35: 386